Archives and Documentation Center
Digital Archives

Design optimization of a continuous detector for PEM imaging with high resolution and DOI capability

Show simple item record

dc.contributor Graduate Program in Biomedical Engineering.
dc.contributor.advisor Güveniş, Albert.
dc.contributor.author Berk, Serkan.
dc.date.accessioned 2023-03-16T13:15:20Z
dc.date.available 2023-03-16T13:15:20Z
dc.date.issued 2006.
dc.identifier.other BM 2006 B47
dc.identifier.uri http://digitalarchive.boun.edu.tr/handle/123456789/19045
dc.description.abstract The objective of this thesis is to improve the resolution of a continuous detector by using an algorithm other than Anger algorithm. Our aim is to obtain a reasonable resolution necessary for Positron Emission Mammography (PEM) imaging. Many research groups have been involved in developing different types of high resolution Positron emission tomography (PET) systems. Among those, most designs have consisted of detectors assembled using tiny discrete crystal elements identified by position sensitive or multichannel photomultiplier tubes. However using narrow, pixellated crystals for higher resolution causes several problems including inter crystal scatter, light collection difficulty, practical difficulties of crystal size, and high cost. In this work, the feasibility of using a continuous crystal detector for PEM imaging with high resolution has been investigated through simulations. We aim to reduce the system cost and to improve system performance. Simulations confirmed that Anger algorithm is not a feasible algorithm to use in a small size detector since it needs further processing to correct the linearity distortion problem and it does not provide any information about the depth of interaction. Simulations also showed that, when calculating the location of interaction with Anger algorithm, there can be a shift about 1 mm depending on the depth of interaction in a 10 mm thick NaI crystal. The nearest neighbor algorithm by using a lookup table gave better results than Anger algorithm and also provided information about depth of interaction. We adapted a second threshold, called Proximity value, to the algorithm to eliminate possible Compton scatterings. This improves the resolution while trading off the number of interactions used. An optimum proximity value has been suggested depending on the simulation results.|Keywords: Positron emission tomography (PET), continuous scintillator, depth of interaction (DOI), Anger logic.
dc.format.extent 30cm.
dc.publisher Thesis (M.S.)-Bogazici University. Institute of Biomedical Engineering, 2006.
dc.relation Includes appendices.
dc.relation Includes appendices.
dc.subject.lcsh Tomography, Emission.
dc.title Design optimization of a continuous detector for PEM imaging with high resolution and DOI capability
dc.format.pages xv, 118 leaves;


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Digital Archive


Browse

My Account