Archives and Documentation Center
Digital Archives

Analyzing the efficiency of the colorimetric technique in determinig the degree of hemolysis of stored blood

Show simple item record

dc.contributor Graduate Program in Biomedical Engineering.
dc.contributor.advisor Ülgen, Yekta.
dc.contributor.author Can, Osman Melih.
dc.date.accessioned 2023-03-16T13:12:37Z
dc.date.available 2023-03-16T13:12:37Z
dc.date.issued 2014.
dc.identifier.other BM 2014 C36
dc.identifier.uri http://digitalarchive.boun.edu.tr/handle/123456789/18840
dc.description.abstract Transfusion has risks of adverse outcomes on patients due to the storage lesions of blood products. Measuring quality of the blood prior to usage can minimize the transfusion related reactions. For controlling the quality of units, experts visually assess the degree of hemolysis by comparing color of blood with graded color charts. Since results are subjective and depend on the spectral energy distribution of the illuminant, the method is inaccurate. Instead of using color charts, color of the stored blood can quantitatively be measured by analyzing the spectrum of the light re ected from the sample with a spectrometer. The color of blood can be de ned as a set of tristimulus values or color coordinates in the color space. In this study daily changes in the colorimetric parameters of stored blood were monitored and correlated with the changes in the degree of hemolysis. Red blood cell (RBC) suspensions collected from 7 male volunteers were used for the study. On each day of storage, 24 colorimetric parameters in various color spaces were measured with a re ection probe that transmits both the incident light from the light source to the blood bag; and the re ected light from the blood bag to the spectrometer. Standard hemolysis measurements with Harboe technique were performed on weekly basis, by taking blood samples from blood bags. Colorimetric parameters: tristimulus X, u', u-v saturation, Hunter a, CIE a*, CIELAB chroma and the correlated color temperature (CCT) changed signi cantly (p<0.05) for each sample after the 3rd week of storage. Except CCT, hemolysis showed good correlation (r>0.65) with the parameters that mostly correspond to red contents of the color stimuli. Hunter a apparently is the most suitable parameter for determining the degree of hemolysis with (r=0.71) (p<0.005).|Keywords : Red Blood Cell Storage, Hemolysis, Storage Lesions, Colorimetry, XYZ color space.
dc.format.extent 30 cm.
dc.publisher Thesis (M.S.) - Bogazici University. Institute of Biomedical Engineering, 2014.
dc.subject.lcsh Blood pressure.
dc.subject.lcsh Erythrocytes
dc.title Analyzing the efficiency of the colorimetric technique in determinig the degree of hemolysis of stored blood
dc.format.pages xiv, 68 leaves ;


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Digital Archive


Browse

My Account