Comparison of particle counting and microbiological sampling methods at-rest and during surgery

Show simple item record

dc.contributor Graduate Program in Biomedical Engineering.
dc.contributor.advisor Ülgen, Yekta.
dc.contributor.author Kavak, Ahmet Emir.
dc.date.accessioned 2023-03-16T13:12:19Z
dc.date.available 2023-03-16T13:12:19Z
dc.date.issued 2011.
dc.identifier.other BM 2011 K38
dc.identifier.uri http://digitalarchive.boun.edu.tr/handle/123456789/18813
dc.description.abstract Air quality monitoring in operating rooms is of prime importance because particles that carry microbiological contamination generate serious risks during surgical operations. Air quality monitoring is executed by two separate methods: Microbiological sampling and particle counting. The aim in this project is to investigate statistical correlation between these two methods. If so, particle counting technique could replace frequent microbiological sampling. Microbiological sampling and particle counting techniques are applied in ve operating rooms located at three di erent hospitals with a total number of 360 measurements taken before (at rest) and during surgery. Spearman's correlation coe cient is used for measuring the level of correlation between two methods. The bacteria counts are classi ed after their sizes and tested for size-by-size correlation. Then, the bacterial counts measured at the same site are cumulatively added together and correlated with the particle counts at each particle size-range. No correlation is found when size-by-size correlation is performed. When cumulative bacteria counts are considered in 'at-rest' conditions, the number of particles in 5.0-10.0 m and 10.0-25.0 m size ranges correlated with bacteria counts. Particles of 1.0-5.0 m size ranges and particles larger than 25.0 m correlated with bacteria counts during surgery.|Keywords : Particle Counting, Microbiological Sampling, Air Quality Monitoring, Operating Rooms, Surgery.
dc.format.extent 30cm.
dc.publisher Thesis (M.S.) - Bogazici University.Institute of Biomedical Engineering, 2011.
dc.subject.lcsh Operating rooms -- Environmental engineering.
dc.subject.lcsh Air -- Microbiology.
dc.subject.lcsh Air quality monitoring stations.
dc.subject.lcsh Indoor air pollution.
dc.title Comparison of particle counting and microbiological sampling methods at-rest and during surgery